1.
Product
Feature |
Medical
Product
under
ISO9002
Approved
from
EuroCERT |
High
Peak
Power
and
Reliable
CW
Oscillating
Power
Output |
Delicate
and
Precision
LASER
Beam
Pattern |
-
100mm
Handpiece
Beam
Spot
Size
1.0mm
-
50mm
Handpiece
Beam
Spot
Size
0.5mm |
Good
Optical
Coherence,
Reliable
Pulse
Quality
&
Human
Ergonomic
Design |
One-Step
Mode
Selection
with
Dial
Switch |
Less
Thermal
Damage
on
Tissue
and
Shorten
Terms
of
Skin
Rejuvenation |
|

|

|

|
1.
About
Control
Panel |
Control
panel
has
an
information
providing
function.
Its
operation
is
simple
and
easy.
The
LCD
window
provides
information
on
the
current
condition
of
the
unit
and
LASER,
selected
output
power,
and
the
procedures
to
follow.
You
can
tell
the
key
is
on
by
the
beep
sound
it
makes
when
pressed.
[Initial
Display
Mode]
WELCOME
TO
USE
SNJ-1000N
->
SELECT
MODE
POWER
---------------
800
Watt
FREQUENCY
------------
10
Hz
PULSE
DURATION
--------
0.1
msec
EXPOSURE
TIME
---------CONTINUE
[Adjustment
Range]
-
POWER
:
1
-
25
Watt
-
FREQUENCY
:
10
-
990Hz
(7
Level-up)
-
PULSE
DURATION
:
0.1ms
-
1.7ms
-
EXPOSURE
TIME
:
CONTINUE,
REPT
(100ms-900ms),
SING
(100ms-900ms) |

[Figure
2-1
Control
Pannel]
|
|
The
following
paragraphs
1-10
are
illustrations
of
the
control
panel
(see
Figure
2-1
Control
Panel). |
1) |
LCD(Information)Window :
Gives
information
on
the
operation
of
the
machine.
Namely,
it
provides
information
on
the
procedures
to
follow,
frequency
and
the
power
selected. |
2) |
ULTRA
Key :
Select
the
operational
mode
of
the
LASER.
The
pre-selected
mode
is
CW
mode.
When
the
key
is
pressed
the
mode
turns
to
Ultrapulse
Wave(ULTRA).
The
mode
alternates
each
time
the
key
is
pressed. |
3) |
FUNCTION
Key :
This
key
is
used
selecting
the
Function
of
the
power,
frequency
and
time. |
4)
5) |
UP/DOWN
key :
This
key
is
used
when
increasing
and
decreasing
the
power
level,
frequency
and
time
(Intensity)is
desired. |
6) |
STANDBY
Key :
This
key
is
used
changing
mode
from
the
treat
mode. |
7) |
READY
Key :
This
key
activates
the
operation.
When
TREAT
is
turned
on
and
Foot
Switch
is
pressed,
the
LASER
light
releases.
The
following
paragraphs |
8) |
CW
Key :
Select
about
the
operational
mode
of
the
LASER.
The
basic
pre-selected
mode
is
Ultra-pulse(ULTRA).
When
the
key
is
pressed
the
mode
turns
to
Continuous
Wave
(CW).
The
mode
alternates
each
time
the
key
is
pressed. |
9) |
EXP
Key :
This
key
selects
skin
tissue
exposure
method.
There
are
continuous
(CONT),
Repeat(REPT),
Single
pulse
(SING)
methods.
The
basic
selection
is
CONT.
The
LASER
light
pulse
continues
for
as
long
as
the
foot
is
pressing
the
foot
switch.
When the
EXP
key
is
pressed,
the
CONT
mode
change
to
REPT
mode.
The
REPT
mode
continues
for
as
long
as
the
foot
switch
is
pressed,
and
the
LASER
radiation
continues
at
regular
cycle.
This
cycle
is
selected
by
DIGITAL
Knob. If
the
EXP
key
is
pressed
again,
the
mode
changes
from
REPEAT
to
SINGLE.
When
SING
mode
is
in
operation,
the
LASER
light
radiates
but
does
not
operate
even
when
the
foot
switch
is
pressed.
This
mode
is
also
selected by
the
UP/DOWN
key. |
10) |
AIMMING
BEAM
Key :
This
key
is
used
the
adjustment
for
the
aiming
beam
the
functions
value. |
11) |
KEY
Switch :
Insert
the
key
in
the
switch
and
turn
it
clockwise.
Then
the
power
goes
on,
and
the
machine
starts
running.
When
the
key
is
turned
counter-clockwise,
the
power
is
shut
off,
and
the
machine
stop
running. |
12) |
STOP
Switch :
Press
the
switch
on
the
machine
in
the
occurrence
of
emergencies. |
13) |
REMOTE
SW.
Connection :
Connect
to
outside
Remote
Interlock
switch. |
14) |
EXT.GND.
Connection :
Connect
to
an
additional
grounding
part
such
as
water
pipe
outside
the
unit. |
15) |
FOOT
SWITCH
Connection :
Connect
the
Foot
Switch |
16) |
AC
INLET :
Connection
of
Line
the
power
source.
And
this
is
device
for
Line
fuse.
The
power
supply
to
the
machine
discontinues
when
the
fuse
is
blown
up. |
|
|
2.
LASER
Emergency
Stop
Switch |
To
immediately
shut
off
the
LASER
system,
press
the
LASER
emergency
stop
switch.
This
is
the
red
switch
located
under
the
key
switch
of
the
console.
To
restore
operation,
again
press
any
button
at
the
control
panel.
Then
set
the
desired
parameters
at
the
control
panel,
press
READY
hen
your
ready
to
fire.
This
switch
is
cont
intended
for
routine
use;
use
the
key
for
routine
shutdown. |
3.
Turning
off
the
Instrument |
3.1
When
treatment
is
complete :
Powering
down
the
LASER
1)
Turn
the
key
to
the
off
(O)
position.
Remove
the
key
to
prevent
unauthorized
use
of
the
LASER.
2)
Remove
the
zoom
handpiece
and
store
it
as
described
later
in
this
chapter.
3)
Fold
the
arm
into
its
closed
position
and
secure
it
by
snapping
it
into
the
arm
clip.
4)
Put
the
dust
cover
on
the
end
of
the
arm.
The
main
power
switch
at
the
back
lower
side
of
the
unit
may
be
left
on.
Turn
off
this
switch
when
unplugging
or
plugging
in
the
power
cord. |
4.
Connecting
the
Handpiece |
4.1
Connecting
the
Handpiece
1)
Remove
the
protective
cap
form
the
distal
end
of
the
articulated
arm.
Inspect
the
distal
end
of
the
articulated
arm.
The
threads
must
be
clean
and
undamaged.
2)
Inspect
the
final
focusing
lens
housing.
If
the
lens
housing
has
been
removed
from
the
handpiece,
carefully
screw
the
focusing
lens
into
the
tapered
cone.
3)
Ensure
that
the
focusing
lens
housing
is
properly
seated
and
is
not
over
tightened.
4)
Attach
the
handpiece
assembly
(focusing
lens,
handpiece)
to
the
articulated
arm
by
threading
the
assembly
into
the
ring
mount
at
the
end
of
the
arm.
Ensure
that
the
handpiece
assembly
is
properly
seated
and
is
not
over
tightened.
4.2
Handpiece
(focus
distance
-
100mm,
50mm)
100mm
and
50mm
Handpiece
can
control
the
spot
size
from
1mm
and
0.5mm
without
replacing
lens.
The
focus
distance
change
by
moving
the
focus
lens
and
it
lens
and
it
change
the
spot
size. |
5.
Cleaning
and
Sterilization |
-Remove
the
handpiece
from
the
arm,
and
put
a
cover
on
the
end
of
the
arm
to
prevent
dust
from
contaminating
the
arm
lenses.
Unscrew
the
focusing
lens
carefully
to
avoid
scratches
and
breakage.
-
When
you
use
a
damp
cloth,
wipe
any
particulate
matter
from
the
surfaces
of
the
handpiece.
Do
not
wipes
the
surface
of
the
focusing
lens
optic.
-
The
handpiece
may
be
disinfected
by
soaking
in
disinfecting
solution
for
at
least
ten
minutes.
The
handpiece
should
be
sterilized
by
flash-sterilization
in
an
autoclave
for
3
minutes
at
270
F |



|
|

|

|

|
1.
Maintaining
your
LASER |
The
SNJ-1000N
CO2
LASER
system
has
been
designed
to give
long,
trouble-free
service.
To
ensure
proper
system
performance,
a calibration
check
should
be performed
at least
once
a year
by a
SNJ
CO.,
Ltd.,
authorized
service
representative.
In
the
unlikely
event
that
the
instrument
fails
to operate
properly,
consult
the
Troubleshooting
Guide
in this
chapter.
If
the
problem
persists,
contact
SNJ
CO.,
Ltd.
Technical
Support
Phone
Call
Center,
Tel:
+82-2-866-9005(Republic
of Korea)
1.1
Cleaning
the
LASER
Console
Clean
the
external
surfaces
of the
LASER
console
periodically
with
a cloth
wetted
with
a spray
disinfectant
cleaner.
Dry
with
a clean,
dry
cloth. |

|
2.
Calibrating
the
LASER |
Under
normal
conditions,
the
instrument's
calibration
should
be cheeked
annually
with
a calibrated
energy
that
power
monitor
is functioning
properly
and
that
the
articulated
arm
system
is aligned.
If the
articulated
arm
delivery
system
is not
aligned,
contact
SNJ
CO.,
Ltd.,
Technical
Support,
82-2-866-9005
(South
Korea).
The
procedures
for
calibration
of the
SNJ
1000
CO2
LASER
are
provided
in document.
This
document
is provided
separate
from
this
manual
and
should
be kept
with
this
manual
and
other
documentation
that
you
may
have
on the
LASER
system. |
3.
Troubleshooting
Guide |
If
the
instrument
will
cannot
turn
on,
check
the
following
items.
-
Verify
that
the
AC power
cord
is plugged
into
the
power
in the
on (
I )
position.
-
Push
down
on fully
engaging
interlocks.
- Check
the
main
power
fuse
on the
back
next
to the
main
power
switch.
- When
the
instrument
is function
on the
back
to fire(and
power
is on):
>
Verify
power
switch
lamp
is illuminated.
>
Verify
the
foot
switch
control
is fully
seated
in its
socket.
- If
still
not
firing,
disable,
power
down
with
key
switch,
wait
2 minutes,
turn
key
back
on.
-
If still
not
firing,
call
SNJ
CO.,
Ltd.,
Technical
Support
Phone
Call
Center,
Tel:
+82-2-866-9005(South
Korea). |
4
Scope
of periodic
maintenance |
Normally,
routine
maintenance
and
service
by staff
is limited
to the
following
procedures:
- Air
flow
system
Replacement
of air
hose
and
verification
of satisfactory
air
flow.
- Optical
system
Routine
inspection
and
cleaning
of accessory
lenses
and
mirrors,
and
routine
verification
of
CO2LASER
beam
and
red
aiming
beam
alignment.
- Electrical
system
Replacement
of blown
fuses
on the
auxiliary
panel,
as required
and
routine
check
for
loose
connections. |
Table
3-1
gives
the
recommended
routine
inspection
and
maintenance
schedule
that
should
be followed
to ensure
reliable
and
continuous
operation
of the
unit. |
INSPECTION/MAINTEANANCE |
FREQUENCY |
PERFORMED
BY |
Check
aiming
and
CO2LASER
Beam
alignment. |
Before
every
operation |
Staff |
Check
for
proper
air
flow. |
Before
every
operation |
Staff |
Replace
air
hose. |
When
change
in
clarity
or
insufficient
air
flow
is
observed |
User |
Inspect
general
condition
of
handpieces,
or
other
operation
LASER
surgical
accessories,
and
check
their
optical
components
for
dust,
smudges
and
scratches.* |
Before
every
operation |
Staff |
Inspect
system
sxterior
to
ensure
that
there
are
no
loose
electrical
connections
or
damage. |
Weekly |
Staff |
Check
maximum
power
calibration |
Every
6
months |
LASER
Industries-authorized
technical
personnel |
Check
coating
and
condition
of
all
mirrors
and
lenses. |
Every
6
months |
LASER
Industries-authorized
technical
personnel |
Check
cooling
system
for
leak
and
obstructions
and
air
pressure
in
the
expansion
diaphragm |
Every
6
months |
LASER
Industries-authorized
technical
personnel |
Perform
power
meter
calibration |
Every
6
months |
LASER
Industries-authorized
technical
personnel |
|
[
TABLE
3-1.
Recommended
Routine
Inspection
and
Maintenance
Schedule
] |

|

|

|
1.
Operational
Command |
1)
If needed,
connect
the
EXT.
GND.
to an
outside
grounding
agent.
2)
If needed,
connect
the
Remote
Interlock
system.
3)
Have
the
articulated
arm
ready.
4)
Prepare
the
foot
switch
and
connect
the
foot
switch
cable.
5)
Connect
the
LINE
terminal
to the
power
outlet. |
Note :
Before
using
the
SNJ1000
CO2
LASER,
the
practitioner
must
read
and
understand
this
entire
manual
and
attend
a
LASER
training
course
that
meets
nationally
recognized
education
curriculum
guidelines.
If
needed,
call
SNJ
CO.,
Ltd.,
Technical
Support
at
Tel:
+82-2-866-9005
(Republic
of
Korea) |
|
1.1
Staring
up the
LASER
1)
Turn
the
Key-switch
clockwise.
Then
the
electric
is supplied
to the
LASER.
2)
When
the
electric
is supplied
to the
unit,
lettered
information
appears
on the
Control
panel.
All
the
functions
are
in operation
mode
at this
time.
1.2
Checking
the
Alignment
of the
Aiming
Beam
Before
operating
the
system,
check
to make
sure
the
brightness
and
alignment
of the
aiming
beam
are
satisfactory.
Alignment
is to
make
sure
the
LASER
beam
is pointing
straight
along
the
line
that
the
aiming
beam
is pointing.
1.3
Warm-Up
Insert
the
key
into
the
key
switch.
Rotate
the
key
clockwise
to the
on (
I )
position
and
release
the
key.
The
pump
and
fan
start
running
and
the
micro0controller
performs
an internal
system
.
The
micro-controller
then
lights
all
the
control
panel
displays
briefly.
1.4
Power
Setting
for
the
Operation
The
intensity
of LASER
beam
can
be adjusted
by the
operator
to fit
his/her
applications
depending
on the
condition
of the
skin
tissues.
Therefore,
following
6 modes
can
be applied
for
the
various
clinical
needs:
1)
CW-CONT
2)
CW-REPT
3)
CW-SING
4)
ULTRA-CONT
5)
ULTRA-REPT
6)
ULTRA-SING
1.4.1
How
to use
CW mode
(1)
Select
CW(Continuous
Wave)
using
the
CW key.
The
LASER
beam
emits
continuously.
(2)
Chose
the
desired
output,
push
the
Power
Up/Down
Button.
The
basic
pre-selected
output
is 5W.
Selection
of output
is possible
within
the
range
of 1-25W,
and
the
intensity
changes
1W at
a time.
(3)
Select
Exposure
mode.
Selections
are
CONT(CONTINUITY),
REPT(REPEAT),
and
ONCE
is selected,
the
output
duration
can
be changed
by REPT/SING
Button.
The
basic
preset
selection
is 500ms.
Selection
can
be made
within
the
range
of 100-900ms
and
by 100ms
increment.
(4)
Press
the
READY
key. This
key
can
be used
after
the
output
selection
has
been
made.
(5)
Press
the
Foot
switch.
The
LASER
beam
starts
emitting.
1.4.2
How
to use
ULTRA
Mode
(1)
Select
ULTRA
(ULTRA
PULSE)
with
the
ULTRA
key. Ultra
Pulse
lets
the
LASER
pulse
its
beam,
instead
of emitting
uninterrupted
beam.
The
output
duration
is very
short.
The
beam
does
not
penetrate
deep
into
skin,
and
enables
peeling
the
skin
thinly.
(2)
The
basic
pre-selected
power
is the
maximum
pulse
(800W).
(3)
Select
the
desired
Exposure
mode.
Selections
are
CONT(CONTINUITY),
REPT(REPEAT),
and
ONCE(SINGLE).
If REPT
or ONCE
is selected,
the
duration
of output
can
be changed
by using
S.On-Time
Up/Down
Button.
The
basis
preset
selection
is 500ms.
Changes
can
be made
within
the
range
of 100-900ms,
and
by 100ms
increment.
(4)
Select
preset
selection
is 10Hz.
The
frequencies
of changes
available
are
10,
20,
50,
100,
200,
500,
and
990Hz.
Selections
are
made
with
F(Hz)
Up/Down
Button.
(5)
Rep.On-Time
Up/Down
Button
adjusts
the
duration
of LASER
beam
emitted
thrusting
the
depths
that
the
LASER
beam
can
be penetrate
into
the
skin.
The
basic
preset
selection
is 0.1ms.
Adjustments
can
be made
within
the
range
of 0.1-1.7ms,
and
0.1ms
increment.
(6)
Press
the
READY
key.
This
key
can
be used
after
the
output
selection
has
been
made.
(7)
Press
the
Foot-switch
key.
The
LASER
beam
starts
emitting.
1.5
Operation
of Foot-switch
When
power
setting
is completed
on the
control
panel,
press
the
READY
key.
This
makes
the
LASER
beam
release
possible.
However,
the
LASER
beam
release
start
when
the
Foot
switch
is pressed.
In other
word,
it is
the
Foot
switch
that
triggers
the
LASER
beam
release. |
2.
Ultra
Pulse
Mode
Selecting
View |

|
|
3.
CW
Mode
Selecting
View |

|
|
5.
CO2
LASER
Theory |
5.1
The
Thermal
Conduction
Procedure
on Tissues
by the
LASER |
|

|
|
5.2
The
Transmission
Range
into
Tissues
upon
LASER
Wavelength |

|
According
to
above
picture,
as
a
range
of
wavelength
10.6¥ìm
for
CO2
Surgical
LASER,
it
can
be
transmitted
into
human
tissues
absorbed
99%
of
water
between
epidermis
and
external
layer,
and
then
some
pulsed
LASER
beam
can
be
transmitted
into
Malpighian
layer
to
rejuvenate
new
skin
because
of
its
exited
collagen
hormone.
Therefore,
concerning a
selection
of
a
Medical
Surgical
CO2
LASER,
it
must
consider
suitable
applications
for
medical
staffs
at
first
as
below |
|
|
Check
Wavelength
|
-
10,600nm(10.6¥ìm) |
High
Peak
Power
and
Stable
CW
Oscillating
Mode
|
-
Peak
Power
800W,
CW
Max.
25W |
Delicate
LASER
Beam
Pattern
|
-
Beam
Spot
Size
1.0mm
at
100mm
Handpiece
-
Beam
Spot
Size
0.5mm
at
50mm
Handpiece |
Good
Optical
Coherence,
Reliable
Pulse
Quality
and
Human
Ergonomic
Design
|
-
Various
Pulse
Rate:
10
~
990Hz
-
Reduce
stress
of
arm
wrist:
Weight-Balance
Articulated
Delivery
Arm
-
One-Step
mode
Selection:
Pulse
Frequency
and
Pulse
Duration |
Less
Thermal
Damage
on
Tissue
and
Shorten
Terms
of
Skin
Rejuvenation
|
-
Ultrapulse
Oscillating
Power
Output
at
Pulse
Frequency
20Hz
and
Pulse
Duration
0.1ms |
|
|
5.3
The
Comparison
Table
of CO2
LASER
Model |
|
SNJ-1000N |
Other
Mediated
LASER |
Oscillating
Mode |
CW
and
Ultra
Pulse(10.6¥ìm) |
CW,
Super
Pulse(10.6¥ìm) |
Thermal
Damage |
Char-Free |
Occasionally |
Pulse
Frequency |
10
~
990Hz |
5
~
100Hz |
Pulse
Duration
TIme |
0.1ms
~
1.7ms |
1.0ms
~
1.7ms |
Setting
Mode
Factor
(Frequency,
Time) |
Frequency
and
Pulse
Duration
Only
(Provide
a
delicate
operating
mode
upon
user's
skill) |
Power
Only
(Frequency/Pulse
Duration) |
Peak
Power |
800W |
300
~
400W |
Dimension |
Compact(W
27
x
D
25
x
H
100cm) |
Medicate
(W
42
x
D
41
x
H
112
cm) |
Functionality |
Delicate
One-Step
Selection |
Complicated |
Application |
-Dermatology:
Pigmented
Nevus,
Black
Spotl
-Plastic
Surgery:
Eye
WrinkleCare,
Skin
Rejuvenationl
-General
Surgery:
Incision,
Excisionl
-ENT:
Tumor
in
ENTl
-Urology:
Phimosis |
-Dermatology
Use
Only |
Miscellaneous |
-Easy
and
Delicate
Functionality
for
User
-Quick
Response
time
by
One-Step
mode
selection
-Suitable
Application
LASER
to
Various
skin
diseases
-Fine
Optical
Coherence,
Stable
Pulse
Mode
Quality
-Minimized
Skin
Thermal
Damage
to
a
Patient
-Suitable
LASER
for
Delicate
Operation
-Equivalent
Incision
Mode
at
Pulse
Mode
as
CW
-Good
Coagulation
at
Surgical
Operation
-Shorten
Skin
Rejuvenation
Terms
-Optimized
Pulse
Signal
Processing
System |
-Fixed
Selection
Mode
-Limited
Application
-Unstable
CW
&
Pulse
Power
-Weak
Peak
Power
and
Pulse
-Complicated
Functionality
-Blocked
Signal
Processing
System |
|

|

|

|
1.
Technical
Specificatons |
-
Dimension
: 27(W)
X 25(L)
X 100(H)cm
-
Weight
: 35kg
-
Max.
Weight
: 45kg
-
Wavelength
: 10,600nm(10.6¥ìm)
-
Pulse
Frequency
: 10
~ 990Hz
-
Pulse
Duration
: 0.1
~ 1.7ms
-
Peak
Power
: 800W
-
Max.
Power
: 25W(1
~ 25W;
CW Mode)
-
Power
Capacity
: 200~240VAC/50~60Hz,
650VA |
|
2.
Packages |
-
Main
Unit:
1 Asy'
-
7 Joint-Articulated
Delivery
Arm:
1 EA
-
Hand
Piece:
50mm
&
100mm
each
1EA
-
Eye
Protect
Goggle:
1 EA
-
Foot
Switch:
1 EA
-
Power
Cable:
1 EA
-
User
Manual:
1 EA |
|
|

|
|
| |
|